Customization: | Available |
---|---|
Type: | Ventilator |
Pressure Limit: | 1.0kpa~6.0kpa |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Specifications
1. Operating Modes: Pneumatically driven & electronically controlled, closed, semi-closed and semi-open
2. Pneumatically driven electrically controlled ventilator, can be used for emergency clinical resuscitation and respiratory therapy
3. Display: Built-in 10.4 inch color TFT fully adjustable display, able to display Pressure-Time, Flow-Time, Pressure-Volume, Flow-Volume or any two waveforms simultaneously on screen
4. Trigger Types: Pressure trigger, Flow trigger
5. Sigh: Ability to insert 1-8 sigh breaths in every 100 breaths, ventilation should be no less than 1.5 the tidal volume
6. Features built-in dual electronic flow sensors and dual respiratory modules
7. Power Failure Support Functions: Automatically converts-standby mode during AC power outages
8. Monitor Parameters: tidal volume, respiration rate, airway pressure, I:E ratio, inspiratory & expiratory status, inspiratory trigger and others
9. Equipped with infrared turbine flow sensor; precisely measures gas flows, stable and reliable
10. 9 Level adjustable humidifier
11. Nonhazardous environmentally friendly frame, precise construction, elegant design, equipped with automated self-checking function during startup and an automatic self-calibrating sensor
12. Alarms: Audible and/or visual alarms for ventilation volume, tidal volume, oxygen concentration, asphyxia, airway pressure, intubation disconnection, low oxygen, power failure and other alarms, also features a alarm history query function
Advanced Model Exclusive Features
Equipped with professional medical grade air compressor tailored for long clinical times and low noise requirements
Air Compressor
1. Air Compressor: 220V AC±10%, 50±1Hz, 700VA, also features good protective grounding against electrical activity
2. Output Gas Pressure: 0.4MPa±20%
3. Continuous output gas flow greater than or equal to 20L/min
4. Instantaneous output gas flow great than equal to 60L/min
Display:10.4 inch high visibility color TFT display
Ventilation Mode:A/C, SIPPV, IPPV, SIMV, PSIMV, PSV, CPAP, PCV, VCV, SPONT MANUAL
Minute Volume:Greater than or equal to 18L
Back-up Power Supply:At least 4 hours
Tidal Volume:Adjustable range: 20-1500ml, Display range: 0-2000ml
Respiratory Rate:1-99bpm
Model |
VM-900BS | VM-900BA |
Display |
10.4 inch high visibility color TFT display |
|
Ventilation Mode |
A/C, SIPPV, IPPV, SIMV, PSIMV, PSV, CPAP, PCV, VCV, SPONT MANUAL |
|
Minute Volume |
Greater than or equal to 18L |
|
Back-up Power Supply |
At least 4 hours |
|
Tidal Volume |
Adjustable range: 20-1500ml, Display range: 0-2000ml |
|
Respiratory Rate |
1-99bpm |
|
Inspiratory/expiratory (I:E) ratio |
4:1-1:4 |
|
PEEP |
0-10cmH2O |
|
SIMV Rate |
1-20bpm |
|
Inspiratory Pressure Trigger |
.-10-10cmH2O |
|
Trigger Sensitivity (flow) |
1-10L/m |
|
Inspiratory Plateau |
Adjustable from 0-50% of inspiratory time |
|
Adjustable Oxygen Concentration |
45-100% |
21-100% |
Gas Supply Requirement |
280~600 kPa medical grade oxygen and compressed air supply |
|
Pressure Limit |
1.0kPa~6.0kPa |
|
Maximum Safe Operating Pressure |
≤6.0kPa |
|
Tidal Volume Alarm |
Upper Limit: 10~2000ml, Lower Limit: 0~1800ml |
|
Airway Pressure Alarm |
Upper Limit: 0.1~6kPa, Lower Limit: 0~5kPa |
|
Oxygen Concentration Alarm |