Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | X Ray Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Specifications
Power Output : 2.5KW
Frequency : 50KHz
X-Ray Tube : Fixed anode Focus : 1.5mm
Tube Voltage : 40-100 KV (Step 1KV)
Tube Current : 25-50 mA
mAs : 1.0~160 mAs (45 steps)
40-49KV |
50 mA |
1-160 mAs |
50-59KV |
42 mA |
1-160 mAs |
60-69KV |
36 mA |
1-140 mAs |
70-79KV |
31 mA |
1-125 mAs |
80-89KV |
28 mA |
1-100 mAs |
90-99KV |
25 mA |
1-80 mAs |
Power Supply : 220V±10 50Hz inner-resistance≤1.0Ω
Operation Method : Wire/Wireless control.
20 meters microwave remote control exposure. (Advantage) It is different from infrared remote control exposure, does not suffer any obstacles in the way.
Standard Configurationt
No. |
Item |
Quantity |
1 |
Combined X-ray generator and high frequency inverted power supply |
1 |
2 |
New main frame of Mobile X-ray system |
1 |
3 |
X-ray equipment control system |
1 |
4 |
Symmetry adjustable collimator with light |
1 |
5 |
Remote control |
1 |
Features:
1. Structure using ergonomic design, compact appearance, convenient operation
2. With high frequency inverter to emit high quality X-ray and low dose on skin, and ensure excellent definition and contrast of pictures
3. With techniques of kV analog closed loop control, mAs digital closed loop control and micro-processing real-time control to ensure precision and repeatability of the dose
4. With kV, mAs two button adjustment, LCD display, multifunction of safety guard
5. With 50 preset exposure programs, and can be modified and stored by the user for convenient operation
6. High-quality knockdown X-ray generator to reduce irradiation is much safer to environment and operator
7. With a symmetrical beam applicator to adjust the X ray field and a collimator lamp to locate the field to ensure accurate radiograph.
Options:
1. PLX152 Table for Mobile X ray Equipment
(2000×700×500mm, cassette movement: 1680mm).
Low bed to facilitate the patient up and down, Longitudinal center of the bed frame with the cassette center line are consistent. To make the center of symmetry when photograph,and the movement range of cassette get larger And have manual brakes convenient location, bed body can 360 ° moving flexible
2. L-100 Upright Bucky Stand.
The height: 1768 mm
Movement range of up and down: 470mm~1468 mm
Grid Density: 103L/INCH
Grid Ratio: 10:1
Focus Distance: 150 cm
Features: with Stationary Filter line, 18" X18"
Can take maximum 17"X17" X ray film