Power | Model IN-1000-1E | 110 / 120 V ac, 50Hz / 60Hz | |||
Model IN-1000-2E | 220 / 240 V ac, 50Hz / 60Hz | ||||
Power Input | ≤400VA | ||||
Refer to IEC60601-1, this equipment belongs to ClassI, Type BF Its operation is continuous |
|||||
Alarm | Power Alarm | Power Failure: Activates if primary power to the Incubator fails or the power wire is accidentally disconnected from the wall receptacle | |||
Fan Alarm | Fan Failure: Activates if Fan motor malfunctions | ||||
Sensor Alarm | Air Sensor Failure: Air Sensor malfunction, refer unit to service | ||||
Deviation Alarm | High Air Temperature: Activated if displayed Air Temperature is 15°C above set point | ||||
Low Air Temperature: Activated if displayed Air Temperature is 25°C below set point | |||||
Over Temperature Alarm | Over Air Temperature: Activated when displayed Air Temperature was approach 38°C for set temperature ≤37°C, or approach 40°C for set temperature >37°C in Air Mode | ||||
System Alarm | System Failure: Activated if Temperature Control System malfunctions | ||||
Temperature Control Range and Correlative Specifications | Air Temperature | 20°C~37°C,for set temperature ≤37°C, 37°C~39°C, for set temperature >37°C | |||
Temperature Rise Time | ≤30min | ||||
Temperature Variability | ±0.5°C | ||||
Temperature Uniformity | ≤1°C | ||||
Environment Requirement | Environment Temperature | Operation Temperature Range | +20°C~+30°C | ||
Store Temperature Range | -40°C~+55°C | ||||
Environment Humidity | Operation Humidity Range | 30%~75% | |||
Store Humidity Range | 10%~100% | ||||
Atmospheric Pressure Range | 700hPa~1060hPa | ||||
Other Specifications |
Noise Level Within Hood Environment | ≤55dB(Environment noise below 45dB) | |||
Carbon Dioxide (CO2) Level within the Hood | Less than 0.5% when a mixture of CO2 in air is delivered at 750ml/min at a point 10cm above the center of the mattress | ||||
Air Velocity Over Mattress | less than 0.3m/s | ||||
Infant Bed Max Load | 10kg | ||||
Transfusion Shelf Max Load | 2kg | ||||
Cabinet Max Load | 6kg | ||||
Function of "SILENCE" Key | Make the alarm to be silence for 10 minutes by press this key | Deviation Alarm | |||
Sensor Alarm | |||||
Fan Alarm | |||||
Factory Default Settings | Temperature Control Mode Air Temperature Mode | ||||
Air Set Temperature: 32°C | |||||
Temperature Units:°C |