STANDARD COMPOSITION:
Servo Control Mode: air temp;
Instant Parameter Displaying: set temp, air temp, heat power rate;
Audible & Visual Alarms: power failure, sensor failure, higher/lower temp, air temperature override, fan failure;
Power failure reset memory and self-test function;
Hood with dual slope: 4 hand-ports.
SPECIFICATION
POWER
Model B-800-1E...........................................................................................................110 / 120 Vac, 50Hz / 60Hz
Model B-800-2E...........................................................................................................220 / 240 Vac, 50Hz / 60Hz
Power Input ................................................................................................................................................ ≤400VA
ALARM
Power Alarm
Power Failure.................................................Activates if primary power to the Incubator fails or the power wire is accidentally disconnected from the wall receptacle.
Fan Alarm
Fan Failure........................................................................................................Activates if Fan motor malfunctions.
Sensor Alarm
Air Sensor Failure........................................................................Air Sensor malfunction, refer unit to service.
Deviation Alarm
High Air Temperature........................................Activated if displayed Air Temperature is 1.5ºCabove set point.
Low Air Temperature............................................Activated if displayed Air Temperature is 2.5ºCbelow set point.
Over Temperature Alarm
Over Air Temperature....................Activated when displayed Air Temperature was approach 38ºC in Air Mode.
System Alarm
System Failure .................................................................Activated if Temperature Control System malfunctions.
TEMPERATURE CONTROL RANGE AND CORRELATIVE SPECIFICATIONS
Air Temperature............................................................................................................................20ºC~37ºC
Temperature Rise Time ..................................................................................................................................................... ≤30min
Temperature Variability................................................................................................................................................ ±0.5ºC
Temperature Uniformity................................................................................................................................................ ≤1ºC
ENVIRONMENT REQUIREMENT
Environment Temperature
Operation Temperature Range.............................................................................................................................+20ºC~ +30ºC
Store Temperature Range.................................................................................................-40ºC~ +55ºC
Environment Humidity
Operation Humidity Range............................................................................................................................................30%~75%
Store Humidity Range...................................................................................................................................................10%~100%
Atmospheric Pressure Range..................................................................................................... 700hPa~1060hPa
OTHER SPECIFICATION
Noise Level Within Hood Environment.............................................. ≤55dB(Environment noise below 45dB)
Carbon Dioxide (CO2) Level within the Hood.......................................................Less than 0.5% when a mixture of CO2 in air is delivered at 750ml/min at a point 10cm above the center of the mattress.
Air Velocity Over Mattress.................................................................................less than 0.35m/s
Infant Bed Max Load............................................................................................................................................10kg
Transfusion Shelf Max Load........................................................................................................................................................2kg
FACTORY DEFAULT SETTINGS
Temperature Control Mode.......................................................................................................................Air Temperature Mode
Air Set Temperature..............................................................................................................................................32ºC
Temperature Units.......................................................................................................................................................ºC
Technical Specifications |
B-3000 |
B-2000 |
B-1000 |
B-800 |
Mattress to Hood |
450mm |
450mm |
450mm |
450mm |
Observation side of hood |
Two incline |
Two incline |
Two incline |
Two incline |
Operate port |
6(2 Iris ports) |
6(2 Iris ports) |
6(2 Iris ports) |
6(2 Iris ports) |
Tubing grommets |
4 |
4 |
4 |
4 |
Front access panel |
826×310mm |
826×310mm |
826×310mm |
826×310mm |
Mattress Tray Size |
630×360mm |
630×360mm |
630×360mm |
630×360mm |
Technical Specifications |
||||
Power requirement |
≤400VA |
≤400VA |
≤400VA |
≤400VA |
Temperature control mode |
Air and skin servocontrol |
Air and skin servocontrol |
Air and skin servocontrol |
Air and skin servocontrol |
Air Temp Control Range |
20ºC ~ 37ºC |
20ºC ~ 37ºC |
20ºC ~ 37ºC |
20ºC ~ 37ºC |
Temperature override mode to |
20ºC ~ 39ºC |
20ºC ~ 39ºC |
20ºC ~ 39ºC |
- |
Skin Temp Control Range |
30ºC ~ 37ºC |
30ºC ~ 37ºC |
- |
- |
Temperature override mode to |
30ºC ~ 38ºC |
30ºC ~ 38ºC |
- |
- |
Skin temp sensor accuracy |
≤0.3ºC |
≤0.3ºC |
- |
- |
Humidity display range |
5% ~ 99% |
- |
- |
- |
Temperature fluctuation |
≤0.5° |
≤0.5° |
≤0.5° |
≤0.5° |
Mattress temperature uniformity |
≤0.8° |
≤0.8° |
≤0.8° |
≤0.8° |
Temperature rise time |
≤30min |
≤30min |
≤30min |
≤30min |
Noise level within hood environment |
≤55dB |
≤55dB |
≤55dB |
≤55dB |
Alarms |
||||
Power failure alarm |
Yes |
Yes |
Yes |
Yes |
Fan failure alarm |
Yes |
Yes |
Yes |
Yes |
Sensor failure alarm |
Yes |
Yes |
Yes |
Yes |
High air temperature alarm |
+ 1.5ºC |
+ 1.5ºC |
+ 1.5ºC |
+ 1.5ºC |
Low air temperature alarm |
- 2.5ºC |
- 2.5ºC |
- 2.5ºC |
- 2.5ºC |
High skin temperature alarm |
+ 1.0ºC |
+ 1.0ºC |
- |
- |
Low skin temperature alarm |
- 1.0ºC |
- 1.0ºC |
- |
- |
Over air temperature alarm |
≤38.0ºC; ≤40.0ºC |
≤38.0ºC; ≤40.0ºC |
≤38.0ºC; ≤40.0ºC |
≤38.0ºC |
Over skin temperature alarm |
≤38.0ºC; ≤39.0ºC |
≤38.0ºC; ≤39.0ºC |
≤38.0ºC; ≤39.0ºC |
- |
System failure alarm |
Yes |
Yes |
Yes |
- |
Alarm silence function |
Yes |
Yes |
Yes |
- |
Operational condition |
||||
Environment temperature |
+20ºC ~ +30ºC |
+20ºC ~ +30ºC |
+20ºC ~ +30ºC |
+20ºC ~ +30ºC |
Environment relative humidity |
5% ~ 99% |
5% ~ 99% |
5% ~ 99% |
5% ~ 99% |
Environment air velocity of flow |
∠0.3m/s |
∠0.3m/s |
∠0.3m/s |
∠0.3m/s |
Others |
||||
RS-232 Connector |
Yes |
Yes |
Yes |
- |
Rail |
Yes |
Yes |
Yes |
- |
Infant bed tilt adjusting |
±10°step-less |
±10°step-less |
±10°step-less |
- |
Mattress tray Max.load |
10Kg |
10Kg |
10Kg |
10Kg |
Transfusion pole Max.load |
2Kg |
2Kg |
2Kg |
2Kg |
Cabinet Max.load |
6Kg |
10Kg |
10Kg |
- |
Packing size(2 cartons) |
100×58×80cm |
100×58×80cm |
100×58×80cm |
100×58×80cm |
Gross Weight |
120Kg |
120Kg |
120Kg |
83Kg |