• in-2000 Hospital Ce Approved Infant Incubator for Sale Baby Incubator
  • in-2000 Hospital Ce Approved Infant Incubator for Sale Baby Incubator

in-2000 Hospital Ce Approved Infant Incubator for Sale Baby Incubator

Certification: CE, ISO13485
Type: Infant Care Equipments
Medical Device Regulatory Type: Type 2
Specification: CE, , ISO
Trademark: Audo
Origin: Jiangsu
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
IN-2000
Production Capacity
1000units Per Month

Product Description

Product feature:
Servo Control Mode: air temperature, skintemperature;
Parameter Displaying: set temperature,air temperature, skin temperature, heat power rate;
Audible & Visual Alarms: powerfailure, sensor failure, higher & lower temp, air & skin temperature override, fan failure, system failure;
>37ºC Preset Mode: power failure reset memory, alarm silence, keypad lock, self-testfunction;
Hood with dual slope; 6 hand-ports;
RS-232 Output Connector (use for networksystem);
IV poles;
Protective guard rail;
Storage cabinets.

in-2000 Hospital Ce Approved Infant Incubator for Sale Baby Incubator

STANDARD COMPOSITION:

 

Servo Control Mode: air temp, skin temp;

Instant Parameter Displaying: set temp, air temp ,skin temp, heater power rate;

Audible & Visual Alarms: power failure, sensor failure, higher & lower temp, air& skin  temp override, fan failure, system failure;

>37ºC Preset Mode: power failure reset memory, alarm silence, keypad lock, self-test function;

Hood with dual slope: 6 hand-ports; left & right cabinets, top-shelf;

RS-232 Output Connector (Use for network system ).

 

 

SPECIFICATION

POWER

Model B-2000-1E.........................................................................................110 / 120 Vac, 50Hz / 60Hz

Model B-2000-2E.........................................................................................220 / 240 Vac, 50Hz / 60Hz

Power Input ......................................................... .... ....... .... ................... ................................... ≤400VA

 

ALARM

Power Alarm

Power Failure.................................................Activates if primary power to the Incubator fails or the power wire is accidentally disconnected from the wall receptacle.

Fan Alarm

Fan Failure.........................................................................................................................Activates if Fan motor malfunctions.

Sensor Alarm

Air Sensor Failure...............................................................................................Air Sensor malfunction, refer unit to service.

Sensor Out of Position................................................................Activated when Sensor is not in correct position to perform calibration or continue operation.

Skin Sensor Disconnected........................................................Activated during Skin Control Mode when Skin Sensor is  disconnected from Temperature Controller.

Skin Sensor Failure........................................................... Activated when Skin Sensor malfunctions.

Deviation Alarm

High Air Temperature......................Activated if displayed Air Temperature is 1.5ºCabove set point.

Low Air Temperature.......................Activated if displayed Air Temperature is 2.5ºCbelow set point.

High Skin Temperature..................Activated if displayed Skin Temperature is 1.0ºCabove set point.

Low Skin Temperature.........................ivated if displayed Skin Temperature is 1.0ºCbelow set point.

Over Temperature Alarm

Over Air Temperature......................................................Activated when displayed Air Temperature was approach 38ºC for set temperature ≤37ºC, or approach 40ºC for set temperature >37ºC in Air Mode.

Over Skin Temperature..................................Activated when displayed Skin Temperature was approach 38ºC for set temperature ≤37ºC, or approach 39ºC for set temperature >37ºC in Skin Mode.

System Alarm

System Failure ...............................................Activated if Temperature Control System malfunctions.

 

TEMPERATURE CONTROL RANGE AND CORRELATIVE SPECIFICATIONS

Air Temperature......20ºC~37ºC,for set temperature ≤37ºC, 37ºC~39ºC,for set temperature >37ºC

Skin Temperature... 20ºC~37ºC,for set temperature ≤37ºC, 37ºC~38ºC,for set temperature >37ºC

Temperature Rise Time ..................................................................................................... ≤30min

Temperature Variability....................................................................................................... ±0.5ºC

Temperature Uniformity................................................................................................... ≤1ºC

Skin Sensor Precision......................................................................................................... ≤0.3ºC

ENVIRONMENT REQUIREMENT

Environment Temperature

Operation Temperature Range.....................................................................................+20ºC~ +30ºC

Store Temperature Range..........................................................................................-40ºC~ +55ºC

Environment Humidity

Operation Humidity Range............................................................................................30%~75%

Store Humidity Range......................................................................................................10%~100%

Atmospheric Pressure Range................................................................................ 700hPa~1060hPa

OTHER SPECIFICATION

Noise Level Within Hood Environment................................. ≤55dB(Environment noise below 45dB)

Carbon Dioxide (CO2) Level within the Hood.......................................................Less than 0.5% when a mixture of CO2 in air is delivered at 750ml/min at a point 10cm above the center of the mattress.

Air Velocity Over Mattress................................................................................less than 0.35m/s

Infant Bed Max Load.......................................................................................................................10kg

Transfusion Shelf Max Load................................................................................................................2kg

Cabinet Max Load ................................................................................................ .............................. 6kg

FUNCTION OF ""SILENCE KEY

Make the alarm to be silence for 10 minutes by press this key, following:

Deviation Alarm

Sensor Alarm

Fan Alarm

FACTORY DEFAULT SETTINGS

Temperature Control Mode................................................................................Air Temperature Mode

Air Set Temperature.....................................................................................................................32ºC

Skin Set Temperature........................................................................................................ ..........34ºC

Temperature Units......................................................................................................................ºC

NOTE: Open Access Panel or Access Door or the use of supplies or other equipment within the Incubator, which can alter the air flow pattern, may effect temperature uniformity, temperature variability, the correlation of the Incubator temperature reading to center mattress temperature and skin temperature.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Import & Export Mode
Have Own Export License
Terms of Payment
T/T, PayPal, Western Union