• Vm-700bi Hospital Ventilator ICU Ventilator Machine
  • Vm-700bi Hospital Ventilator ICU Ventilator Machine
  • Vm-700bi Hospital Ventilator ICU Ventilator Machine

Vm-700bi Hospital Ventilator ICU Ventilator Machine

Type: Ventilator
Kind: Breathing Apparatus
Certification: CE, ISO13485
Group: All
Medical Device Regulatory Type: Type 2
Anesthesia: Others
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
VM-700BI
Safety Valve
<12.5 Kpa
Peep
0 ~ 1.0 Kpa
Respiratory Rate
1 ~ 99 Bpm
Ptr
-10 ~ 10 Hpa
Transport Package
Individual Packing
Specification
CE, ISO
Trademark
Audo
Origin
Jiangsu, China
Production Capacity
1000units Per Month

Product Description

VM-700BI Hospital Ventilator ICU Ventilator Machine
Vm-700bi Hospital Ventilator ICU Ventilator Machine
Specifications
Technical Specifications:
Gas requirement:
Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa
safety valve
<12.5 kPa
Respiratory Rate
1 ~ 99 bpm
Oxygen concentration output
21% ~ 100% adjustable
Maximum Minute ventilation
≥18L / min
modes of ventilation
A/C, IPPV, SIPPV, IMV, SIMV, PEEP. MANUAL, SIGH, SPONT
Ventilator compliance
≤30 Ml/kPa
PEEP:
0 ~ 1.0 kPa
Ptr:
-10 ~ 10 hPa
IMV frequency:
1~20 bpm
I/E Ratio:
4:1~1:4, Has the inverse ratio ventilation
Tidal Volume
Setting Range: 50~1500ML Display Range: 0~2000ml ; resolution ratio: 10ml
Operating conditions
Ambient temperature:
10 ~ 40ºC
Relative humidity:
no higher than 80 %
Atmospheric pressure:
860 hPa ~ 1060 hPa
Power requirement:
100-120 Vac, 50/60 Hz;
Safty & Alarm
Gas source pressure
Immediate alarm; "high level alarm" indicator flickers raising an audible alarm.
Airway Pressure Alarm
The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The "high level alarm" indicator flickers raising an audible alarm.
Tidal Volume Alarm
Lower than 50ml, The alarm will be raised after one breathing cycle.
Ventilation Volume Alarm
Lower: 0~12L/Min; Up: 18L/ Min
Battery Voltage Alarm
It alrms when the battery voltage is lower than 10.5V.
Power On Self Test
Self test before working, assure it's working normally.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Import & Export Mode
Have Own Export License
Terms of Payment
T/T, PayPal, Western Union