• Ba-401 Clinical Lab Fully Automatic Biochemistry Chemistry Analyzer/Blood Analysis / Reagent
  • Ba-401 Clinical Lab Fully Automatic Biochemistry Chemistry Analyzer/Blood Analysis / Reagent
  • Ba-401 Clinical Lab Fully Automatic Biochemistry Chemistry Analyzer/Blood Analysis / Reagent
  • Ba-401 Clinical Lab Fully Automatic Biochemistry Chemistry Analyzer/Blood Analysis / Reagent
  • Ba-401 Clinical Lab Fully Automatic Biochemistry Chemistry Analyzer/Blood Analysis / Reagent
  • Ba-401 Clinical Lab Fully Automatic Biochemistry Chemistry Analyzer/Blood Analysis / Reagent

Ba-401 Clinical Lab Fully Automatic Biochemistry Chemistry Analyzer/Blood Analysis / Reagent

Classification: Biochemical Apparatus
Type: Fully-Auto Chemistry Analyzer
Certification: CE, ISO13485
Group: All
Medical Device Regulatory Type: Type 2
Warranty: 12 Months
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
BA-401
Calibration
Linear, Non-Linear, Multi Point, K Fa
Light Source
Halogen Lamp
Absorbance Resolution
0.0001A
Language
English, French, Spanish, German, Russian
Lead Time
Within 7 Days
Reagent Position
80
Sample Position
80 Positions
Power Supply
220V or 110V, 50~60Hz
Analytical System
Fully Automatic, Random Access, Discrete
Assay Item
80 Assay
Transport Package
Carton
Specification
CE, ISO
Trademark
Audo
Origin
Jiangsu, China
Production Capacity
5000units Per Month

Product Description

BA-401 Clinical Lab Fully Automatic Biochemistry Chemistry Analyzer/Blood Analysis / Reagent

Ba-401 Clinical Lab Fully Automatic Biochemistry Chemistry Analyzer/Blood Analysis / Reagent
 

Product name: Fully-auto biochemistry analyzer

Item No.: BA-401

Application:

Biochemistry Analyzer is designed for hospital or clinical laboratory to measure the quantity of chemical or biochemical components in human serum, urine and other liquid sample, used to test liver function, kidney function, cardiac markers, blood sugar, blood lipid, etc.

 

 Technical Specifications: 

Model

BA-401

Analytical System

Fully automatic, Random Access, Discrete

Method

End point, Rate, Fixed time, Immunoturbidimetric, 1-2 regent, Multistandard, reagent/serum blank, etc

Assay Item

80 assay

 

ISE mould(K+, Na+, Cl-, Ca2+) available on request

Throughput

1 Reagent

400 tests/hr

 

2 Reagent

400 tests/hr

 

With ISE

120 tests/hr

Test Menu

T.BILI         r-GT/GGT    CHO    Ca      APOB-1/B   CHE

 

D.BILI        ALP/AKP     TG      CL      APOB       CREA

 

TP           UREA        CK      P       CK-MB      Mg

 

ALB          CREA        LDH    C        ASO        AFU

 

Lactic Acid    ALT/GPT      UA    α-HBDH  CO2        FMN

 

LP(a)         AST/GOT     GLU   AMY      LDL-C      HDL-C

 

CHE          LA           TBA    ADA      HS-CRP    PA

 

Fe            Cu           Zn     C3       C4          IgG

 

IgM           IgA           and drug, toxicity,etc.

Sample Position

80

 

Including standard, control and STAT; either serum cup or primary tube available

Sample Volume

1~100ul, 0.1ul/step

Reagent Position

2X40

Reagent Volume

R1: 1~400ul, 0.1ul/step, R2: 1~400ul, 0.1ul/step

Reagent/Sample Probe

With liquid level sensor, collision sensor, Teflon coating and automatic washing station

Reaction Time

0~999 seconds

Cuvette

High quality uv-transmitted plastic cuvette.

Cuvette Washing

8 channels automatic washing system for reaction cuvettes

Probe and Mixer Washing

Independent washing station for each sample/reagent probe and mixer

Alarm

Automatic alarm for malfunction (eg: collision, reagent/sample insufficiency, full waste container, etc)

Calibration

Linear, Non-linear, Multi standard, K factor

Sample Dilution/Retest

Sample can be diluted and retested if results are out of range or sample is insufficient. Also with calibrator auto diluting function

Wavelength

340-810nm

Light Source

Halogen lamp

Absorbance Resolution

0.0001A

Absorbance Accuracy

±0.0003A(0-2.5A)

Repeatability

±2%

Quality Control

Levy jennings quality control program at 3 levels

Barcode

Optional

Printer

Multiple report formats available

System

Windows XP; Windows 7

Power Supply

220V or 110V, 50~60Hz

Dimension

100×85×75(cm)

Weight

135kg

Features:  

l Random access fully automatic biochemistry analyzer

l New concept and more friendly software

l Automatic washing station for both sample and reagent probe

l Liquid level detection and collision protection for both sample and reagent probe

l Reliable cooling system for reagent chamber, condensate cooling design and peltier cooling system double ensure the cooling effect.

l Powerful reaction cuvette washing system

l ISE Unit & barcode scanner (optional)

l Lower waste and pro-environment

 

Structure:

1. Optical System

Light source: Halogen-tungsten lamp, 2000hours working life about

Wavelength: 340nm-810nm

Linear range:0~3ABS

2. Sample System

a) Sample tray: 80 sample position, available to use serum cup or blood tube

b) Sample volume:1~100ul, programmed by 0.1ul step

c) Sample probe: Liquid level detection and collision protection automatically

d) Probe cleaning: automatic washing both inside and outside, Carryover<0.1%

e) Automatic sample dilution

3. Reagent System

a) Reagent tray: 80 positions for single &dual Reagents.

b) Refrigeration: Refrigerated reagent

c) Compartment 24h Cooling system maintaining temperature 2~8°C

d) Reagent volume:1~400ul, programmed by 0.1ul step

e) Reagent probe: Liquid level detection and collision protection automatically

f) Pre-heating function.

g) Real-time monitoring of reagent volume and auto alarm

h) Probe cleaning: automatic washing both inside and outside, Carry over<0.1%

4. Reaction System

a) Reaction tray: 90 reaction cuvettes, High quality UV-transmitted plastic cuvettes adopt, flat design to ensure heating evenly

b) Back-Dividing-Light technology

c) Min Reaction volume: 180ul

d) Reaction Temperature:37°C+0.1°C

e) Mixing system: Independent mixing probe

f) Automatic washing cuvettes

5. Washing System

a) Automatic cleaning Sample/mixer probe 

b) Five channels washing station for each cuvette

c) Automatic record and deduct cuvette blank value

6. Operation Unit

Operation system: Windows XP or WIN 7

Interface: RS-232

7. Working Conditions

a) Power Supply: 220V±10%, 50/60HZ; 110V (optional)

b) Power consumption: ≤1200VA

c) Temperature:15~30°C

d) Humidity: ≤85%

e) Water consumption: 10L/h
 

Advantage of Our Company

1. Professional medical products manufacturer

2. High quality with competitive price

3. Independent Design and Outstanding Sales Team

4. Large Supply Ability

5. Excellent after-Sales service

 
Shipping & Packing:

Ba-401 Clinical Lab Fully Automatic Biochemistry Chemistry Analyzer/Blood Analysis / Reagent   Ba-401 Clinical Lab Fully Automatic Biochemistry Chemistry Analyzer/Blood Analysis / Reagent
 


Contact us:



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now