Customization: | Available |
---|---|
Type: | Ventilator |
Display: | 10.4′′ LCD Display |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
TECHNIQUES SPECIFICATIONS |
|
Physical specifications |
|
Display |
10.4'' LCD Display |
Mode |
pneumatically powered and electrically controlled system |
Trolley |
Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
Technical Specifications |
|
Gas requirement |
Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa |
safety valve |
<12.5 kPa |
Respiratory Rate |
1 ~ 99 bpm |
gas concentration output |
21% ~ 100% adjustable |
Maximum Minute ventilation |
≥18L / min |
modes of ventilation |
A/C, SIPPV(VCV),IPPV(VCV),SIMV,PSIMV,CPAP,PCV,PEEP,SIGN,SPONT, MANUAL |
Ventilator compliance |
≤30 Ml/kPa |
PEEP |
0 ~ 1.0 kPa |
Ptr |
-1.0kPa~1.0kPa |
IMV frequency |
1~20 bpm |
I/E Ratio |
4:1~1:4, Has the inverse ratio ventilation |
Tidal Volume |
Setting Range: 50~1500ML Display Range: 0~2000ml ; resolution ratio: 10ml |
Inspiratory Plateau |
0~1s |
Maximum Safety Pressure |
≤ 6.0kPa |
Sigh |
one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point |
Pressure limit range |
1.0~ 6.0kPa |
Airway pressure alarm: Audible and visual and with yellow and red color indicating |
Lower: 0.1 kPa ~ 6.0 kPa; Upper: 0 ~ 5.0 kPa |
±0.2 kPa |
|
Ventilation Volume alarm |
≥ 18L/ MIN |
Power Supply Alarm |
Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep >120s |
Operating conditions |
|
Ambient temperature |
10 ~ 40oC |
Relative humidity |
no higher than 80 % |
Atmospheric pressure |
860 hPa ~ 1060 hPa |
Power requirement |
100-120 Vac, 50/60 Hz; |
Attention: the AC power supply used for the ventilator machine must be well grounded. |
|
Attention: the ventilator machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. |
|
Storage |
|
Ambient temperature |
-15oC ~ +50oC |
Relative humidity |
no higher than 95 % |
Atmospheric pressure |
86 kPa ~ 106 kPa. |
It should be stored in a room without corrosive gas and well ventilated |
|
Package |
|
packaging box |
comply with the requirement of GB/T 15464 |
Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation |
|
Moisture protection and rain protection to ensure that product is protected from natural damage. |
|
Safty & Alarm |
|
Gas source pressure |
Immediate alarm; "high level alarm" indicator flickers raising an audible alarm. |
Airway Pressure Alarm |
The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The "high level alarm" indicator flickers raising an audible alarm. |
Tidal Volume Alarm |
Lower than 50ml, The alarm will be raised after one breathing cycle. |
Ventilation Volume Alarm |
Lower: 0~12L/Min; Up: 18L/ Min |
Battery Voltage Alarm |
It alrms when the battery voltage is lower than 10.5V. |
Power On Self Test |
Self test before working, assure it's working normally. |
STANDARD CONFIGURATIONS |
|
QTY |
NAME |
1 set |
Main unit |
4 pcs |
Adult threaded pipe (Silica) |
1 set |
Child threaded pipe (single use) |
1 pc |
Oxygen Tube |
1pc |
Y-Pipe |
2pcs |
Mask (Silicom) |
2pcs |
Leather Bag |
2pcs |
Fuse |
1pc |
Power Line |
1pc |
Oxygen pressure reducer |
4 pcs |
Hoop |
1pc |
Battery |
1pc |
Tools Attachment |
1 set |
humidifier |
1 set |
English Version User Manual |