Hospital 5 Inch Tabletop BlueTooth patient monitor PM-2000A
PM-2000A Tabletop Multi-Parameter Monitor
Five parameters:ECG,NIBP,SPO2,PR,TEMP.
Waveform:ECG and SPO2 waveforms.
Features:
Ø Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data;
Ø Build-in rechargeable Li-battery, up to 15 hours running time, support AC and DC power;
Ø Adjustable audible and visual alarms, and sensor off alarm;
Ø Long time monitoring and sleeping monitoring;
Ø Easy to carry, suitable for ambulance center, has the stand for fixing;
Prior:
Ø Storage and review data up to 3888groups via Trend Graph and Trend List.
Ø USB and Bluetooth data upload;
Ø Big font screen interface is easy to observe;
Ø Back light can be adjusted;
Ø Optional Bluetooth printer to print the waveform and data out.
Ø Optional 5leads and 5leads+ETCO2
Specification:
1. General Specifications:
Size: 160mm×160mm×100mm
Net Weight: 750g
Display Specification
Measurement Display: color TFT- LCD/touch screen
Power Supply Indicator: Dual-color LED (red/green)
Charging indicator: A green LED
2. Power Supply
AC Power Adaptor
Input: 100~240VAC, 50/60Hz, 0.7A
Output: DC 5V, 1.5A
Battery
Li-ion rechargeable battery, 3.7V/7200mAH
Operating Time: 15 hours with full battery capacity.
(Condition: 25ºC, NIBP working period is 15 minutes)
Recharge Time: 10 hours.
3. Environment
Temperature
Working:0C~45C
Transport and Storage: -25C~85C
Humidity
Working:30% ~85 %
Transport and Storage: 30% ~95 % (no condensation)
4. Monitoring Parameter
ECG
Input:3- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation
Heart Rate
Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±1 bpm
Alarm Mode: Audible and visual alarm
SpO2
SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution: 1bpm
Accuracy: ±1bpm
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using blood pressure measurement device.
Temperature
Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0ºC~50ºC
Accuracy: ±0.1ºC
5. Storage and Review
Maximum Data Quantity: 3888 groups
Maximum Trend Time: Continuous 129.6 hours
6. Printer (optional)
Type: Thermal micro-printer
Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm
Interface: Bluetooth wireless interface
Recording Types: Real-time printing and review data printing
Power Supply:
Rechargeable battery 1700mAh~2000mAh.7.2V.
Charge(discharge) ≥1000times.
Charge time: 2hours
Work Operation/relative humidity:0~55ºC/10~80%RH
Storage Operation/relative humidity:-20~60ºC/10~90%RH
Standard accessories
Standard Packing List |
Color palm patient monitor main unit |
1 pc |
3-lead ECG cable ( include surface TEMP probe) |
1pc |
Adult finger SpO2 sensor |
1 pc |
Adult NIBP cuff |
1 pc |
NIBP extension tube |
1 pc |
AC power adapter |
1 pc |
The operator's manual |
1 pc |
Selectable Accessory |
Pediatric NIBP cuff |
|
Pediatric finger Spo2 sensor |
|
Neonatal wrap SpO2 sensor |
|
Bluetooth printer |
|
5Leads |
|
5Leads+ETCO2 |
|
Detailed images:
Contact us: