in-800 Ce Mobile Approved Newborn Baby Neonatal Infant Incubator

Product Details
Customization: Available
Customized: Customized
Certification: CE, ISO13485
Manufacturer/Factory, Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Import & Export Mode
Have Own Export License
Terms of Payment
T/T, PayPal, Western Union
  • in-800 Ce Mobile Approved Newborn Baby Neonatal Infant Incubator
  • in-800 Ce Mobile Approved Newborn Baby Neonatal Infant Incubator
Find Similar Products

Basic Info.

Model NO.
IN-800
Scale
Medium
Type
Infant Incubator
Mode
Air Skin
Power
≤400va
Air Temp Control Range
20ºC-37ºC
Skin Temp Control Range
20ºC-37ºC
Transport Package
Carton
Specification
CE, ISO
Trademark
Audo
Origin
Jiangsu, China
Production Capacity
1000 Piece/Pieces Per Month

Product Description

IN-800 CE Mobile Approved Newborn Baby Neonatal Infant Incubator
in-800 Ce Mobile Approved Newborn Baby Neonatal Infant Incubator
Standard Composition
 1 Servo Control Mode: air temp;
 2 Instant Parameter Displaying: set temp, air temp, heat power rate;
 3 Audible & Visual Alarms: power failure,  sensor failure, higher/lower temp, air temperature override, fan failure;
 4 Power failure reset memory and self-test function;
 5 Hood with dual slope: 4 hand-ports
 
Specification
Power Model IN-800-1E 110 / 120 V ac, 50Hz / 60Hz
Model IN-800-2E 220 / 240 V ac, 50Hz / 60Hz
Power Input ≤400VA
Refer to IEC60601-1, this equipment belongs to ClassI, Type BF 
Its operation is continuous
Alarm Power Alarm Power Failure: Activates if primary power to the Incubator fails or the power wire is accidentally disconnected from the wall receptacle
Fan Alarm  Fan Failure: Activates if Fan motor malfunctions
Sensor Alarm Air Sensor Failure: Air Sensor malfunction, refer unit to service
Deviation Alarm High Air Temperature: Activated if displayed Air Temperature is 15°C above set point
Low Air Temperature: Activated if displayed Air Temperature is 25°C below set point
Over Temperature Alarm Over Air Temperature: Activated when displayed Air Temperature was approach 38°C in Air Mode
System Alarm System Failure: Activated if Temperature Control System malfunctions
Temperature Control Range and Correlative Specifications Air Temperature 20°C~37°C
Temperature Rise Time ≤30min
Temperature Variability ±0.5°C
Temperature Uniformity ≤1°C
Environment Requirement Environment Temperature Operation Temperature Range +20°C~+30°C
Store Temperature Range -40°C~+55°C
Environment Humidity Operation Humidity Range 30%~75%
Store Humidity Range 10%~100%
Atmospheric Pressure Range 700hPa~1060hPa
Other
Specifications
Noise Level Within Hood Environment ≤55dB(Environment noise below 45dB)
Carbon Dioxide (CO2) Level within the Hood Less than 0.5% when a mixture of CO2 in air is delivered at 750ml/min at a point 10cm above the center of the mattress
Air Velocity Over Mattress less than 0.3m/s
Infant Bed Max Load 10kg
Transfusion Shelf Max Load 2kg
Factory Default Settings Temperature Control Mode Air Temperature Mode
Air Set Temperature: 32°C
Temperature Units:°C

 
NOTE: Open Access Panel or Access Door or the use of supplies or other equipment within the Incubator, which can alter the air flow pattern, may effect temperature uniformity, temperature variability, the correlation of the Incubator temperature reading to center mattress temperature and skin temperaturein-800 Ce Mobile Approved Newborn Baby Neonatal Infant Incubator
 
in-800 Ce Mobile Approved Newborn Baby Neonatal Infant Incubator
in-800 Ce Mobile Approved Newborn Baby Neonatal Infant Incubator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More